Package Include:
1 x Receiver: S6CA-DC-ANT3
1 x Transmitter: CD-6
1 x User manual
Application:
This is long range 1000 meters DC power 12V 24V wireless remote control switch kit with 6 channels dry relay output (Normally open and normally closed) radio receiver and a 6 buttons RF transmitter.
For long distance remote control DC and AC equipments, such as lights, lamp,motor, pump, linear actuators, doors, windows, electric solenoid valves, etc.
Feature:
Wireless control, easy to install.
Two operating voltage versions: DC 12V, 24V optional.
Relay Output: This receiver is dry relay output; it can be used to operate both DC and AC equipment. The output terminals are NO / NC (normally open / normally closed), serving as a switch.
With external antenna, the receiver has a farther working range.
The transmitter / remote can control the receiver from any place within a reliable working distance.
Wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.
The receiver has reverse voltage protection and overcurrent protection.
The receiver can only be triggered by paired transmitters.
One or more transmitters / remotes can control one or several receivers simultaneously.
Two or more receivers may be used in the same area.
Receiver Parameters:
Model: S6CA-DC-ANT3
Operating Voltage: 12±1VDC (model S6CA-DC12), or 24±2VDC (model S6CA-DC24), the operating voltage must be specified when ordering.
Working Frequency: 433.92 MHz
Quiescent Current: ≤10mA
Channel: 6 CH
Output Type: Dry Relays Output (With Normally Open and Normally Closed Terminals)
Maximum Load Voltage of Relay: 240VAC or 28VDC
Maximum Load Current of Relay: 10A / channel
Suitable Wires for Connecting Terminals: 22-14 AWG
6 Selectable Working Modes: Self-locking, Momentary, Interlocking, Self-locking + Momentary, Momentary + Interlocking
Operating Temperature: -20 °C ~ +70 °C
PCB size: 75 x 58 x 16 mm (3.0 x 2.3 x 0.6 inches)
Case size: 95 x 62 x 28 mm (3.7 x 2.4 x 1.1 inches)
Transmitter Parameters:
Model No.: 0021088 (CD-6)
Channel / Button: 6
Button Symbol: 1,2,3,4,5,6
Waterproof case, antenna and buttons, it can be used outdoors.
Operating Voltage: 9V (1 x 6F22-9V battery)
Operating Current: 30mA
Operating Frequency: 433.92 MHz
Modulation Mode: ASK
Encoding Chip: SC2260-R4
Encoding Type: Fixed code by soldering, up to 6561 codes
Transmitting Distance: 1000 meters / 3000 feet (theoretically)
Operating Temperature: -20°C ~ +70°C
Unit Size: 150 x 50 x 30 mm (5.9 x 2.0 x 1.2 inches)
Matching Transmitters:
This receiver only works with the transmitter CD-6 .
Working Range:
The receiver and the transmitter CD-6 form a complete kit, the maximum working distance may reach 3000 feet or 1000 meters in an open area.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no interference. But in the practice, it will be hindered by trees, walls, or other construction, and will be interfered by other wireless signals. Therefore, the actual working distance may not reach this maximum distance.
Usage:
The receiver can be used to control both 0~28VDC and 110~240VAC devices.
Notice: The receiver is dry relay output, not DC/AC power output. Initial state of relay output terminals: Terminals <COM> and <NO> are Normally Open; Terminals <COM> and <NC> are Normally Closed.
Wiring:
1) If you want to control a DC 12V lamp, do as following:
1.1 Connect the positive pole of DC power supply to terminal <V+>, and connect the negative pole of DC power supply to terminal <V->.
1.2 Connect terminal <NO> to the positive pole of DC power supply, connect terminal <COM> to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.
2) If you want to control an AC 220V lamp, do as following:
2.1 Connect the positive pole of DC power supply to terminal <V+>, and connect the negative pole of DC power supply to terminal <V->.
2.2 Connect terminal <NO> to the live wire of AC power supply, connect terminal <COM> to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.
Setting different working modes:
1) Setting Self-locking mode: When the receiver is in the learning status, press the button 1 on the transmitter.
The operation of Self-locking mode with the transmitter CD-6:
Press the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.
Press the button 1 again: The relay 1 is deactivated, and the connected lamp 1 is turned off.
............
Press the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on.
Press the button 6 again: The relay 6 is deactivated, and the connected lamp 6 is turned off.
2) Setting Momentary mode: When the receiver is in the learning status, press the button 2 on the transmitter.
The operation of Momentary mode with the transmitter CD-6:
Press and hold the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.
Release the button 1: The relay 1 is deactivated, and the connected lamp 1 is turned off.
............
Press and hold the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on.
Release the button 6: The relay 6 is deactivated, and the connected lamp 6 is turned off.
3) Setting Interlocking mode: When the receiver is in the learning status, press the button 3 on the transmitter.
The operation of Interlocking mode with the transmitter CD-6:
Press the button 1 on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on. Other 5 relays are deactivated and other 5 connected lamps are turned off.
............
Press the button 6 on the transmitter: The relay 6 in the receiver is activated, and the connected lamp 6 is turned on. Other 5 relays are deactivated and other 5 connected lamps are turned off.
4) Setting Self-locking (Channels 1~3) + Momentary (Channels 4~6) mode: When the receiver is in the learning status, press the button 4 on the transmitter.
5) Setting Self-locking (Channel 1) + Momentary (Channels 2~6) mode: When the receiver is in the learning status, press the button 5 on the transmitter.
The operation with the transmitter CD-6:
6) Setting Momentary (Channels 1~2) + Interlocking (Channels 3~6) mode: When the receiver is in the learning status, press the button 6 on the transmitter.