Package Include:
3 x Receiver: S2U-AC
1 x Transmitter: CV-6
1 x User manual
Application:
This is long range 110V 220V 10A wireless remote control switch kit, with three 2 channels 10A relay output radio receivers, and one 6 buttons RF transmitter.
It can control DC and AC electrical equipments, such as lamps, lights, LED lighting, motors, fans, pump, solenoid valves, etc.
Feature:
Wireless control, easy to install.
Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
Universal input: Support 110V AC (110V~120V) used in US, Canada, etc, and 220V AC (220V~240V) used in Germany, UK, France, etc.
Relay Output: This receiver is dry relay output; it can be used to operate both DC and AC equipment. The output terminals are NO / NC (normally open / normally closed), serving as a switch. That means you should also connect a separate power supply to equipment.
Each channel can work at maximum current 10A.
The transmitter / remote can control the receiver from any place within a reliable working distance.
Wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.
The receiver has reverse voltage protection and overcurrent protection.
The receiver can only be triggered by paired transmitters.
One or more transmitters / remotes can control one or several receivers simultaneously.
Two or more receivers may be used in the same area.
Receiver Parameters:
Model: S2U-AC
Operating Voltage: AC110~240V (110V/120V/220V/240V)
Working Frequency: 433.92 MHz
Quiescent Current: ≤6mA
Channel: 2 CH
Output Type: Dry Relay Output (With Normally Open and Normally Closed Terminals)
Maximum Load Voltage of Relay: 240VAC or 28VDC
Maximum Load Current of Relay: 10A / channel
Suitable Wires for Connecting Terminals: 22-12 AWG
4 Selectable Working Modes: Self-locking, Momentary, Interlocking, Momentary + Self-locking
Operating Temperature: -20 °C ~ +70 °C
PCB size: 88 x 80 x 18 mm (3.5 x 3.1 x 0.7 inches)
Case size: 115 x 90 x 55 mm (4.5 x 3.6 x 2.2 inches)
Transmitter Parameters:
Model No.: 0021019 (CV-6)
Channel/Button: 6
Button Symbol: 1, 2, 3, 4, 5, 6
Operating Voltage: 12V (1 x 23A -12V battery)
Operating Current: 15mA
Operating Frequency: 433.92MHz
Transmitting Distance: 500m / 1500ft (theoretically)
Modulation Mode: ASK
Operating Temperature: -20 ° C to +70 ° C
Unit Size: 110mm x 50mm x 18mm
Matching Transmitters:
The receiver can work with different transmitters, such as model CV-6 (500 meters / 1500 feet range), CD-6 (Industrial, Waterproof, 1000 meters / 3000 feet range), or CB-6 (1000 meters / 3000 feet range).
Working Range:
With a transmitter (such as CV-6) to form a complete set, the maximum working distance can reach 500 meters in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
IIf you need a longer working distance, you can replace the antenna on the receiver, or use an RF signal repeater, or use a powerful transmitter, such as a CB-6 transmitter.
Usage:
The receiver can be used to control both 0~28VDC and 110~240VAC devices.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals <COM> and <NO> are Normally Open; Terminals <COM> and <NC> are Normally Closed.
Setting different working modes:
1) Setting Momentary mode: Press the learning button in the receiver 2 times, signal LED continuously flashes 2 times and then goes off.
The operation of Momentary mode with the transmitter CV-6:
Press and hold the button 1 on the transmitter: The relay 1 in the receiver 1 is activated, and the connected lamp 1 is turned on.
Release the button 1: The relay 1 in the receiver 1 is deactivated, and the connected lamp 1 is turned off.
Press and hold the button 2 on the transmitter: The relay 2 in the receiver 1 is activated, and the connected lamp 2 is turned on.
Release the button 2: The relay 2 in the receiver 1 is deactivated, and the connected lamp 2 is turned off.
Press and hold the button 3 on the transmitter: The relay 1 in the receiver 2 is activated, and the connected lamp 3 is turned on.
Release the button 3: The relay 1 in the receiver 2 is deactivated, and the connected lamp 3 is turned off.
Press and hold the button 4 on the transmitter: The relay 2 in the receiver 2 is activated, and the connected lamp 4 is turned on.
Release the button 4: The relay 2 in the receiver 2 is deactivated, and the connected lamp 4 is turned off.
Press and hold the button 5 on the transmitter: The relay 1 in the receiver 3 is activated, and the connected lamp 5 is turned on.
Release the button 5: The relay 1 in the receiver 3 is deactivated, and the connected lamp 5 is turned off.
Press and hold the button 6 on the transmitter: The relay 2 in the receiver 3 is activated, and the connected lamp 6 is turned on.
Release the button 6: The relay 2 in the receiver 3 is deactivated, and the connected lamp 6 is turned off.
2) Setting Self-locking mode: Press the learning button in the receiver 3 times, signal LED continuously flashes 3 times and then goes off.
The operation of Self-locking mode with the transmitter CV-6:
Press the button 1 on the transmitter: The relay 1 in the receiver 1 is activated, and the connected lamp 1 is turned on.
Press the button 1 again: The relay 1 in the receiver 1 is deactivated, and the connected lamp 1 is turned off.
Press the button 2 on the transmitter: The relay 2 in the receiver 1 is activated, and the connected lamp 2 is turned on.
Press the button 2 again: The relay 2 in the receiver 1 is deactivated, and the connected lamp 2 is turned off.
Press the button 3 on the transmitter: The relay 1 in the receiver 2 is activated, and the connected lamp 3 is turned on.
Press the button 3 again: The relay 1 in the receiver 2 is deactivated, and the connected lamp 3 is turned off.
Press the button 4 on the transmitter: The relay 2 in the receiver 2 is activated, and the connected lamp 4 is turned on.
Press the button 4 again: The relay 2 in the receiver 2 is deactivated, and the connected lamp 4 is turned off.
Press the button 5 on the transmitter: The relay 1 in the receiver 3 is activated, and the connected lamp 5 is turned on.
Press the button 5 again: The relay 1 in the receiver 3 is deactivated, and the connected lamp 5 is turned off.
Press the button 6 on the transmitter: The relay 2 in the receiver 3 is activated, and the connected lamp 6 is turned on.
Press the button 6 again: The relay 2 in the receiver 3 is deactivated, and the connected lamp 6 is turned off.
3) Setting Interlocking mode: Press the learning button in the receiver 4 times, signal LED continuously flashes 4 times and then goes off.
The operation of Interlocking mode with the transmitter CV-6:
Press the button 1 on the transmitter: The relay 1 in the receiver 1 is activated, and the connected lamp 1 is turned on; The relay 2 in the receiver 1 is deactivated, and the connected lamp 2 is turned off.
Press the button 2 on the transmitter: The relay 2 in the receiver 1 is activated, and the connected lamp 2 is turned on; The relay 1 in the receiver 1 is deactivated, and the connected lamp 1 is turned off.
Press the button 3 on the transmitter: The relay 1 in the receiver 2 is activated, and the connected lamp 3 is turned on; The relay 2 in the receiver 2 is deactivated, and the connected lamp 4 is turned off.
Press the button 4 on the transmitter: The relay 2 in the receiver 2 is activated, and the connected lamp 4 is turned on; The relay 1 in the receiver 2 is deactivated, and the connected lamp 3 is turned off.
Press the button 5 on the transmitter: The relay 1 in the receiver 3 is activated, and the connected lamp 5 is turned on; The relay 2 in the receiver 3 is deactivated, and the connected lamp 6 is turned off.
Press the button 6 on the transmitter: The relay 2 in the receiver 3 is activated, and the connected lamp 6 is turned on; The relay 1 in the receiver 3 is deactivated, and the connected lamp 5 is turned off.
4) Setting Momentary (Channel 1) + Self-locking (Channel 2) mode: Press the learning button in the receiver 5 times, signal LED continuously flashes 5 times and then goes off.